Interbus interface
Leuze electronic GmbH + Co. KG
AMS 384
i
51
TNT
35/7-2
4V
9
Interbus interface
9.1
General information on Interbus
The AMS 384
i
is designed as an Interbus device.
The data output format of the AMS 384
i
is defined via the default settings. The baud rate of
the data to be transmitted is 500 kbit/s by default and can be configured to 2Mbit/s.
Note!
The Interbus interface can be activated/deactivated via the display. With activated Interbus,
the abbreviation "IBS" is shown in the display.
9.2
Interbus - Electrical connection
Figure 9.1: Interbus - Electrical connection
BUS IN
DI 3
2
1
4
Data
GND
/DO
/DI
DO
5
BUS OUT
DO 1
2
3
4
/DO
/DI
DI
Data
GND
5
M12 connector
(B-coded)
M12 socket
(B-coded)
BUS IN (5-pin plug, B-coded)
BUS OUT (5-pin socket, B-coded)
Pin
Name
Comment
Pin
Name
Comment
1
DO
From the Interbus master
1
DO
From the Interbus master
2
/DO
From the Interbus master,
inverted
2
/DO
From the Interbus master,
inverted
3
DI
To the Interbus master
3
DI
To the Interbus master
4
/DI
To the Interbus master,
inverted
4
/DI
To the Interbus master,
inverted
5
Data
GND
Data Ground
5
Data
GND
Data Ground
Thread
SHIELD Shield via RC element on the
housing
Thread
SHIELD Shield directly on the housing