Description ODSL 30
Leuze electronic GmbH + Co. KG
ODSL 30
25
3.6
Operation ODSL 30
Indicators and operational controls
Figure 3.9: Indicators and operational controls ODSL 30
3.6.1 LED indicators ODSL 30
3.6.2 Switching on
After switching on and following error-free initialization of the device, the green LED PON illuminates
continuously: the ODSL 30 is in measure mode. The display lighting remains switched off.
In measure mode, the LC display shows the current measurement value in millimetres. If no object is
detected or if the signal is too weak, the notice
NO SIGNAL
appears on the display.
PON
Q1
Q2
Q3
ENTER
Device LEDs
Two-line LC display with 16 charac
-
ters each
Key pad with 3 buttons
Leuze electronic
Dist. [mm] 10687
LED
Color
Display when
Sensor operation
Activated teach-in
characteristic output
curve
1)
1) The teach-in process is described in detail in Section 3.4.1 and Section 6.3
PON
Green, continuous
light
Ready
Teach event
Green, flashing
–
Teach event
Green off
No voltage
Q1,
Q2,
Q3
Yellow, continuous
light
Object within teach-in measurement dis
-
tance
Teach event
Yellow flashing
–
Teach event
Yellow off
Object outside teach-in measurement
distance or no signal present
NOTE
The 3 yellow LEDs Q1, Q2 and Q3 for the status display of the up to 3 switching outputs are
additionally located in the optical window of the ODSL 30. Only the LEDs for those switching
outputs that are actually available in the respective device model have a function.
Leuze electronic
Dist. [mm] 10687
NOTE
After an operating time of 30 min., the device has reached the operating temperature required
for an optimal measurement and should be referenced then.