Description ODSL 30
Leuze electronic GmbH + Co. KG
ODSL 30
16
Teaching always takes place towards the upper switching point (see figure 3.6 on page 16). The lower
switching point is set to the value '199' by default and can be adjusted via the operating menu. The
following table applies for a lower switching point of 199mm.
3.4.2 ODSL 30/24… with three switching outputs
Switching outputs ODSL 30/24…
Figure 3.6: Behavior of the switching outputs ODSL 30/24… (PNP output active high)
Behavior of the switching outputs of the ODSL 30/24…
The ODSL 30/24… is equipped with three independent switching outputs, each with 2 switching points
(switching window). The upper switching points can be taught using a teach line. By configuring within the
measurement range, it is possible to set the lower and upper switching points, the switching hysteresis,
the switching behavior (light/dark switching), and the type of switching output (PNP high active or NPN low
active or PNP/NPN push-pull).
Teaching always takes place towards the upper switching point (see Figure 3.6). Each of the lower
switching points is set to the value '199' by default and can be adjusted via the operating menu. The
following table applies for a lower switching point of 199mm.
Object distance
Light switching
Dark switching
Output Q1
Output Q1
No object (no signal)
Off
On
< 200mm
1)
On
Off
< teach value
On
Off
> teach value
Off
On
1) Only if a reception signal is available that can still be evaluated, otherwise same as "no object"
Hysteresis
Measurement distance
ON
OFF
Lower
switching point
Upper
switching point
(teach-in)
Hysteresis
ON
OFF
PNP output active high
Light switching
Dark switching
Object distance
Light switching
Dark switching
Output Q1 Output Q2 Output Q3 Output Q1 Output Q2 Output Q3
No object (no signal)
Off
Off
Off
On
On
On
< 200mm
1)
On
On
On
Off
Off
Off
< teach value
On
On
On
Off
Off
Off
> teach value
Off
Off
Off
On
On
On