4.2.1
Supply wiring
The test monitoring unit TNT 35 is supplied with 24V DC +/- 15%. The max. current
consumption is 200mA.
The +24V supply voltage is connected to terminal 5 and the GND is connected to
terminal 6.
Figure 4.2-1:
Supply wiring
5 6
8
7
13 14 15 16
21 22 23 24
29 30 31 32
Sensor
Start/Active
EDM
OFF/ON
TNT35
+24V GND