4.2
Electrical Installation
Warning!
The electrical installation is only to be performed by specialised personnel.
Supply and signal lines have to be installed separately from power lines during installation.
Inside the switching cabinet, suitable spark extinction has to be provided if using
contactors.
When installing drive motors and brakes, the corresponding installation manuals have to be
observed.
The power supply for the TNT 35 must be equipped with a protective mains separation
device according to IEC 60742. The power supply unit used to operate the TNT 35 has to
be able to compensate for changes and interruptions of the supply voltage acc. to
EN 61496-1.
Figure 4.1-2:
Display elements TNT 35
5 6
8
7
13 14 15 16
21 22 23 24
29 30 31 32
Sensor
Start/Active
EDM
OFF/ON
TNT35