Function and Commissioning of the TNT 35
4.1
Function characteristics of the safety system
The complete safety system consists of a TNT 35 and accompanying protective photoelec-
tric sensors or light barriers.
After the TNT 35 is switched on via the start input, the functionality of the protective
photoelectric sensors is monitored in two-second cycles.
The electrical integration into the controller has to be performed acc. to the corresponding
safety category acc. to ISO 13849-1. The voltage free safety relay outputs can be directly
used for shut-down of the dangerous movement.
Inside the monitoring unit TNT 35, a selectable start- and restart-disable, as well as a
selectable relay monitoring input are integrated.
4.1.1
Display and Operating Instruments
The test monitoring unit TNT 35 features integrated LEDs to indicate the state of the
system.
The start- and restart-disable, as well as the relay monitoring functions are set on the
TNT 35 using the corresponding jumpers on the connection terminals.
Figure 4.1-1:
Installation of the complete safety system
24
14
32
31
30
29
7
8
6
5
13
23
22
16
21
15
}
Transmitter
Active
Op
erat
io
n w
it
h sta
rt-/
a
nd re
start-
di
sabl
e
Op
erat
io
n w
it
hou
t start
-/
a
nd re
start-
di
sabl
e
Receiver
The operating mode is selected using a jumper
between:
terminal 22 & 23 (with start-/restart-disable)
or
terminal 23 & 24 (without start-/restart-disable)
The device is shipped from the factory with the
jumper set between terminal 22 and 23
(with start-/restart-disable function)
EDM (relay monitoring, feedback circuit)
Emergency
shut-down
Safety output 2
Safety output 1
Message output "Safety
On"
}
TNT 35
Start/
Active
Reset
GND
+24V