Configuring the safety sensor
Leuze electronic
RSL 410
66
1
Configuration Wizard
Figure 9.1: Safety configuration using Configuration Wizard
9.4
Configuring protective function
Prerequisites: The safety distance, additional distances and protective field dimensions and contours have
been determined according to the mounting position (see chapter 7.1.1 "Calculation of safety distance S").
In the initial screen, click the
CONFIGURATION
tab.
The CONFIGURATION menu opens with the options:
•
Administration
•
OSSDs
If the
OSSDs
option is selected in the CONFIGURATION menu, the
Protective function A
option is
displayed.
•
Outputs
•
Other
9.4.1 Creating simple safety configuration
To create a safety configuration for simple commissioning, you must first perform five configuration steps
to access the editor used for defining the contours of the protective and warning fields.
[]By clicking Next, you can proceed to the next configuration step without selecting the corresponding
option in the CONFIGURATION menu.
If you make changes to the default settings in a configuration step, first click the [Confirm] button and then
[Next].
Administration
OSSDs
Protective function A
The device manager (DTM) starts without querying the access level of the user. During commu
-
nication with the safety sensor, the safety sensor does however query the access level of the
user. To change the access levels, see chapter 9.7 "Selecting access level".