Functions
The functions of the safety sensor must be matched to the respective application and its safety require
-
ments. You can activate/deactivate the functions and adapt them using parameters. You configure the
functions with the help of the configuration and diagnostics software (see chapter 9 "Configuring the safety
• You configure the functions of the safety sensor in the software as configuration projects.
• In each configuration project you determine the protective function and the configurable field pairs
via the selected function mode.
• The changeover-capable protective/warning field pairs for the selected function mode are defined in
configuration banks.
• You determine the resolution, the start-up behavior, the response time and, where applicable, the
vehicle speed together for all protective/warning field pairs of a configuration bank.
5.1
Authorization concept of safety sensor
User management allows target-group-oriented communication between the software and the safety
sensor. Which functions are available depends on the selected access level of the user. For information
on the software and on user management (see chapter 4 "Configuration and diagnostic software
• Changing the safety configuration as well as the communication and diagnostics settings of the sen
-
sor is only permitted for certain access levels.
• Installation and operation of the software do not depend on the access level of the user.
The following access levels are available: