Installation and mounting
Leuze electronic
RFM - HF RFID Series
33
TNT
35/7-2
4
V
•
RFM 62 SL 200
:
via four fastening holes in the device with 4 M4 screws
RFM 62 fastening via four fastening holes
Figure 5.3:
RFU 62 fastening holes
5.3
Mounting of the transponders
Self-adhesive transponder
When affixing, the surface must be dry, grease-free and clean in order to ensure secure
bonding. In the vicinity of the chip, the self-adhesive transponders must not be mounted
around corners or edges as damages could result. Recommended distance to metal/metal
foils: > 5mm. Intended for use in mechanically protected environments.
Disc transponder
Screw connection of the disc transponders only with sufficient play. Excessive tightening
of the fastening screw may result in damage to the transponder. Recommended distance
to metal/metal foils: > 5mm. Also suitable for areas with slight mechanical loading.
High temperature transponder
High material expansions are possible due to high temperature differences that may occur
by using these transponders. The fastening of these transponders must, thus, absolutely
be loose.
Fastening holes
for 4 x M6 screws