Configuration / Parameter Setting
#Leuze
#Leuze electronic
GmbH + Co KG, Postfach 11 11, D-73277 Owen/Teck, In der Braike1, D-73277 Owen/Teck, Tel. ++49 (0)7021/5730, Fax ++49 (0)7021/573199
Page 24 of 28
LZ - ELE - BA - GB - 0006 - 06
Date: 01.12.2004
4.1.7 Module SSI interface
The module SSI interface uses no inputs and no outputs and is used only for the
parameterization of the SSI interface of the laser.
corresponding parameters:
SSI data bits
24 Bit (default)
Number of SSI data bits = 24
25 Bit
Number of SSI data bits = 25
26 Bit
Number of SSI data bits = 26
Code
Gray
(default)
SSI output code = Gray
Binary
SSI output code = Binary
SSI error bit
The SSI error bit is an additional bit in the SSI protocol and is attached after the
"LSB bit".
disabled (default)
No SSI error bit
Temperature
SSI error bit = Temperature
The bit is set, if the device temperature is outside of the
range from 0 - 50 °C. A low range deviation has still no
influence on the measurement and is therefore to be
regarded as a warning.
Intensity
SSI error bit = Intensity
The bit is set, if an intensity value of smaller 8% is present,
or the laser beam is interrupted and leads to the error value
output (see "Module Error Display", page 21).
Hardware
SSI error bit = Hardware
The bit is set, if an internal hardware error were noticed and
leads to the error value output
(see "Module Error Display", page 21).
The SSI output value specifies the value, which is output on the SSI interface.
Position (default)
Output of the Laser position
Intensity
Output of the Laser intensity value
Speed
Output of the Laser actual speed