Configuration / Parameter Setting
#Leuze
#Leuze electronic
GmbH + Co KG, Postfach 11 11, D-73277 Owen/Teck, In der Braike1, D-73277 Owen/Teck, Tel. ++49 (0)7021/5730, Fax ++49 (0)7021/573199
Page 20 of 28
LZ - ELE - BA - GB - 0006 - 06
Date: 01.12.2004
4.1.1 Module Position
The module uses two input words which are consistently transferred via the bus. The
position of the Laser Measuring Device is transferred via these two input words.
Position of the I/O data in the input double word ID x
LSB
MSB
Input byte x+0
Input byte x+1
Input byte x+2
Input byte x+3
corresponding parameter data:
Resolution
Sets the resolution of the measurement system.
The available options are:
Centimeter
Millimeter (Default)
1/10 millimeter
1/100 millimeter
Inch
1/10 Inch
Free resolution (in 1/100 mm), valid values are 1 - 65535, default = 100
Count direction
Sets the count direction of the measurement system.
The available options are:
positive (default)
position values increasing
negative
position values decreasing