4 Configuration / Parameter setting via the Profibus-DP master
The configuration of the laser occurs alternatively via the configuration software of the
Profibus-DP - master or via the OMSConfiguration Tool-software. With a download of
the control parameters the parameters, which were configured via the
OMSConfigration Tool-software, will be overwritten by the control.
In this instruction only the configuration via the Profibus-DP - master is described. The
PC program OMSConfiguration Tool is described in an instruction of its own.
4.1 Modular configuration
Since all functions of the Laser Measuring Device are used not at any time, individual
functions can be disabled on the bus.
For this, in the mask of configuration software of the profibus master, the Laser
Measuring Device is represented as a modular compact device .
That means after insertion of the laser into the configuration list of the master, the
corresponding configuration list at first is empty.
Every module requires inputs and outputs and has a parameter data set. The
parameter data set must be set dependent of the application.
That the laser starts at the profibus, in the configuration list at least one module
must be entered.
i
Important note:
It exist configuration programs which include an "universal module".
This module is not defined in the device master file of the laser and must not be
used.