2 Assembly instructions
The adjustment of the laser measuring device in the vertical plain is carried out via
four studs
(A)
in the mounting plate. The adjustment in the horizontal plane can be
made by four hexagon bolts
(B)
. It has to be taken into account that the screw
diameter is approx. 1-2 mm smaller than the through bore of the mounting plate. Exact
dimensional properties are on the dimensional drawing in the rear part of the
document.
A
B
Figure 2: Mechanical adjustment possibilities
2.1 Aligning of the laser light spot to the reflector / foil inclination
The laser beam of the OMS2 must be on the reflecting foil at any time. This can be
done using the light spot of the laser diode, which is still clearly visible on the
reflecting foil even at long distance. When aligning the laser measuring device, the
user may need to take measures to ensure that it can be mechanically adjusted.
The size of the reflecting foil must be such that the light spot cannot be displaced from
the reflector by vibrations. The laser light spot must always be on the reflecting foil to
100%.
With the shipment of the OMS/120 a reflection foil with the size of 20 x 20 [ cm ] is
provided. Other sizes can be ordered on request.
For the laser measuring device OMS/170 a special reflector (Fresnel Retro Reflector)
Art.-No.: 500 36208 must to be used.
i
Note
Reflecting foils by other manufacturers should be used only after consultation with
Leuze electronic, as all the information in the "Specifications" chapter refers to the foil
already supplied with the device.