Starting up the device
Leuze electronic
ODS 9
43
Teaching the offset value via IO-Link system commands
Value
hex / dec
Command
Description
0xC2 / 194
Teach Preset To Offset
At the time the calculation is performed, the off-
set is corrected so that the nominal value stored
under Preset is output.
7.2
Setting measurement value processing and filtering
Ä
Set the measure mode using the display and the control buttons (Application menu item; see chapter
3.4.5 "Application menu") or using the
Sensor Studio
configuration software (see chapter 8 "Connecting
• Standard
Multi-purpose mode (factory setting)
• Precision
Higher accuracy for measurement tasks with lower dynamics requirements
• Ambient light
For measurements in which increased ambient light occurs.
• Less dynamic
• Increased response times
7.3
Reset to factory settings
Configuration is performed using the OLED display and the keyboard (see chapter 3.4 "Configuration /
menu structure") or using the
Sensor Studio
configuration software (see chapter 8 "Connecting to a PC –
To reset the sensor via the OLED display and keyboard, proceed as follows:
Ä
Switch off the voltage supply or disconnect the sensor from the voltage supply.
Ä
Press the enter button
and hold down the button.
Ä
Switch on the voltage supply or connect the sensor to the voltage supply.
• The LEDs for PWR and switching output flash.
Ä
Press the enter button
again.
ð
The sensor restarts, reset to the factory settings.
7.4
IO-Link interface
7.4.1
Overview
The sensors are equipped with an IO-Link 1.1 interface for configuration and measurement data output.
• The sensor transfers data packets in the TYPE_2_V process data format.
• The process data length is 32 bits. Eight status bits, eight scale bits and 16 measurement value bits are
transferred. On the control-side, you can only use the measurement value bits.
• Of the eight possible control input bits, bit 0 is available for deactivation (control signal
Transducer Dis-
able
).
• The sensor cyclically transfers (minCycleTime = 0.5 ms) data packets at a baud rate of 230.4 kBaud
(COM3).
• The process data and parameters along with the corresponding system commands are described in the
IO Device Description (IODD file).
Ä
Download the IODD file from the Internet (
).
Ä
Unpack the ZIP archive to a separate directory. The supplementary HTML files contain a description in
tabular form in German and English.
• You can configure the sensor using the
Sensor Studio