Starting up the device - Configuration
Leuze electronic
MSI-MD-FBX
31
8.2
Setting the operating mode
The muting controller is equipped with two DIP switch blocks, each with eight switches for setting the con-
figuration.
1
2
1
DIP switch blocks
2
Service USB connection
Fig. 8.1:
Muting controller without cover
Switch position of the DIP switch blocks
NOTICE
Error for different switch positions in the DIP switch blocks!
An error is triggered for different switch positions in the DIP switch blocks and the OSSDs switch
off.
Ä
When configuring, make certain that the switch position is identical in both DIP switch
blocks.
1
2
3
4
5
6
7
8
A
B
1
1
2
2
A
DIP switch block A
B
DIP switch block B
1
Switch position ON
2
Switch position OFF
Fig. 8.2:
Example: switch position of the DIP switch blocks
Tab. 8.1:
Assignment of the DIP switches
DIP
switch
Function
ON
OFF
1
Number of the muting sen-
sors
4-sensor muting
(not permissible)
2-sensor muting
2
Muting mode
Sequence controlled muting
(not permissible)
Timing controlled muting
3
EDM
With EDM
Without EDM
4
Restart
Manual restart
Automatic restart
5
Muting-enable
With muting-enable
Without muting-enable
6
Muting timeout
With muting-timeout exten-
sion
Without muting-timeout exten-
sion