Ordering information and accessories
Leuze electronic
MLC 510 AS-i Host/Guest
53
15
Ordering information and accessories
Nomenclature
Part designation:
MLCxyy-za-hhhhei-ooo
Tab. 15.1:
Part number code
MLC
Safety sensor
x
Series: 3 for MLC 300
x
Series: 5 for MLC 500
yy
Function classes:
00: Transmitter
01: Transmitter
02: Transmitter with test input
10: Basic receiver - automatic restart
11: Basic receiver - automatic restart
20: Standard receiver - EDM/RES selectable
30: Extended receiver - blanking/muting
z
Device type:
T: transmitter
R: receiver
a
Resolution:
14: 14 mm
20: 20 mm
30: 30 mm
40: 40 mm
90: 90 mm
hhhh
Protective field height:
150 … 3000: from 150 mm to 3000 mm
e
Host/Guest (optional):
H: Host
MG: Middle Guest
G: Guest
i
Interface (optional):
/A: AS-i
ooo
Option:
EX2: explosion protection (zones 2 + 22)
/V: high Vibration-proof
Tab. 15.2:
Part descriptions, examples
Examples for part desig-
nation
Properties
MLC500T14-600H/A
Type 4 Host transmitter, PL e, SIL 3, resolution 14 mm, protective field
height 600 mm, with AS-i
MLC500T30-900MG
Type 4 Middle Guest transmitter, PL e, SIL 3, resolution 30 mm, protective
field height 900 mm