![Leuze electronic LSIS 472i M45-I1 Operating Instructions Manual Download Page 19](http://html1.mh-extra.com/html/leuze-electronic/lsis-472i-m45-i1/lsis-472i-m45-i1_operating-instructions-manual_1884019019.webp)
Mounting
Leuze electronic
LSIS 472i
19
6
Mounting
The device can be mounted in the following ways:
• Mounting using a mounting device on the fastening grooves on the rear of the device or on the nar
-
row side of the device.
• BT 56: Mounting on a rod
• BT 59: Wall mounting
• Mounting via M4 mounting thread:
• on the rear side of the device
• on the front side of the device
• on the narrow side of the device
6.1
Installation instructions
6.2
Mounting with BT 56 mounting device
Mounting with a BT 56 mounting device is intended for rod mounting. For ordering information, see
Mount the BT 56 on the rod with the clamp profile (system-side).
Mount the device with its fastening grooves on the clamping jaws of the BT 56 with limit stop at end.
Secure the device with the M6 screw terminal.
Maximum tightening torque for the M6 screw terminal: 8 Nm
6.3
Mounting with BT 59 mounting device
Mounting with a BT 59 mounting device is intended for wall mounting. For ordering information, see
Mount the BT 59 mounting device on the system side with M8 fastening screws (included in delivery
contents).
Mount the device with its fastening grooves on the clamping jaws of the BT 59 with limit stop at end.
Secure the device with the M6 screw terminal.
NOTICE
Observe during mounting!
Make certain that the required environmental conditions (humidity, temperature) are maintained.
Affix the markings for compartment fine positioning according to the working distance:
Rack Near
: hole or reflector
Rack Far
: reflector only
Make certain that the area behind a hole is not obstructed.
With closed profiles, only reflectors may be used as markings.
There must not be a light source behind a hole.
Avoid glossy, reflective surfaces behind the holes.
The surface surrounding a hole must reflect diffusely, i.e., no glossy surfaces.
Avoid interfering contours in the camera's field of view, e.g., stamped numbers.
Make certain that there is only one marking (hole or reflector) in the capture range of the smart camera.
Screw heads with identical diameter must not be located in the capture range of the smart camera.
Make certain that the lens cover of the smart camera is oriented parallel to the marking (hole or reflec
-
tor).
Make certain that the marking (hole or reflector) is located as close to the middle of the capture range
of the smart camera as possible.
Make certain that the camera window is not soiled, e.g., by leaking fluids, abrasion from boxes or res
-
idues from packaging material.