Commissioning and configuration
Leuze electronic
LSIS 4xx
i
36
TNT
35/7-2
4
V
6
Commissioning and configuration
6.1
Establishing a connection between PC and LSIS 4xx
i
6.1.1
Starting the device
Apply the supply v18 … +30VDC (typ. +24VDC).
The camera starts up and the following message appears on the display:
6.1.2
Establishing an Ethernet connection
The Ethernet connection is used as the host interface and for configuring the LSIS 4xx
i
via
a PC with a browser.
Notice!
In order for the PC and LSIS 4xx
i
to communicate with one another, both must be on the
same subnet and have different network addresses.
Normally, it is sufficient to adjust the Ethernet settings (= TCP/IP configuration) on one of the
two devices (LSIS 4xx
i
/PC) to those of the other device.
If the PC is normally connected to a network using DHCP address assignment, the easiest
way to access the LSIS 4xx
i
is to create an alternative configuration in the TCP/IP settings
of the PC. This method lends itself if the LSIS 4xx
i
is not connected to an existing network
during later operation. For further information on this topic, refer to chapter 6.1.3.
Alternatively, you can also integrate the LSIS 4xx
i
in an existing network and configure it
from a PC that is also connected to the network. For further information on this topic, refer
to chapter 6.1.4.
Startup...
Leuze electronic
GmbH + Co. KG
After a few seconds, brief device information appears.
LSIS 412i M43 W1
Leuze electronic
GmbH + Co. KG
SW: V 0.51.0 HW:0
SN: 0902-082905016
Afterwards, the LSIS 4xx
i
switches to normal operation
and displays the active interfaces as a status message.