Electrical connection
Leuze electronic
LSIS 4xx
i
32
TNT
35/7-2
4
V
5.2.1
PWR - voltage supply and switching inputs/outputs 1 to 4
Preferably, use the "KD S-M12-8A-P1-…" ready-made cables, see table 9.6 "PWR
cables for the LSIS 4xxi" on page 54.
Supply voltage
Attention!
For UL applications, use is only permitted in class 2 circuits in accordance with the NEC
(National Electric Code).
The smart cameras of the LSIS 4xx
i
series are designed in accordance with safety class III
for supply by PELV (protective extra-low voltage) / SELV (safety extra-low voltage).
Connecting functional earth FE
Ensure that the functional earth (FE) is connected correctly. Unimpaired operation is only
guaranteed when the functional earth is connected properly. All electrical disturbances
(EMC couplings) are discharged via the functional earth connection.
Switching input / output
The smart cameras LSIS 4x2
i
feature 8 freely programmable, opto-decoupled switching
inputs / outputs
IO1 … IO8
.
The switching inputs can be used to activate various internal functions of the LSIS 4xx
i
(triggering of image acquisition, check program selection …). The switching outputs are
used for the output of result and status messages and for triggering an external flash control.
Switching inputs/outputs
IO1
to
IO4
are located on the
PWR
M12 connector.
Switching inputs/outputs
IO5
to
IO8
are located on the
BUS OUT
M12-socket.
PWR (8-pin connector, A-coded)
Pin
Name
Remark
1
VIN
Positive supply v18 … +30VDC
2
IO1
Configurable switching input/output 1
3
GND
Negative supply voltage 0VDC
4
IO2
Configurable switching input/output 2
5
IO3
Configurable switching input/output 3
6
IO4
Configurable switching input/output 4
7
NC
Not Connected
8
FE
Functional earth
Thread
FE
Functional earth (housing)
Table 5.1:
Pin assignments - PWR
PWR
IO1
IO2
IO3
IO4
NC
VIN
GND
FE
7
M12 plug