Configuration using online commands
#
Technical description LSIS 22x
Leuze electronic
8
Configuration using online commands
Configuration can be performed via the RS 232 interface or via the USB interface with COM
port emulation with online commands.
Examples for online commands
Example 1
:
To, e.g., configure a <STX> as prefix, the following command string must be sent:
<SYN>M<CR>PREBK29902.
The response from the LSIS 22x is:
PREBK29902<ACK>.
If an
<ENQ>
is sent as response, the command syntax was incorrect.
If an
<NAK>
is sent, the command could not be executed because the permissible value/
range was exceeded.
Notice!
If no response is received to the sent command, the interface is probably not correctly set.
Example 2
:
To deactivate Code 128 as a readable code, the following command string must be sent:
<SYN>M<CR>128ENA0.
The response from the LSIS 22x is:
128ENA0<ACK>.
Notice!
The commands correspond to the content of the configuration codes that are printed in this
technical description. For further information on the topic of online commands, please con-
tact Leuze electronic.