Configuration using configuration codes
68
Technical description LSIS 22x
Leuze electronic
7.5.20
QR Code code selection
By reading in one of the following configuration codes, reading of the
QR Code
code type
is activated or deactivated. In addition, it is possible to configure the number of digits that
are to be read (value range for number of digits: 1 … 7089, factory setting: 1 … 7089).
Figure 7.43: Configuration codes for activating/deactivating the QR Code code type
Notice!
To set the minimum or maximum number of digits, please first read in the above configura-
tion code and then the digits for the desired number of digits (see "Programming codes for
the configuration" on page 92). Conclude parameter entry by reading in the
Save
program-
ming code.
Read code type QR Code ON
Read code type QR Code OFF
QR Code - standard settings
QR Code - minimum number of digits
QR Code - maximum number of digits