Configuration using configuration codes
Leuze electronic
Technical description LSIS 22x
33
TNT
35/7-2
4
V
7.1.2
USB parameter - LSIS 223 M5M-R1
By reading in the following configuration code, the USB interface is set to the following
standard parameters for
USB keyboard emulation
(factory setting):
• USB operating mode
USB keyboard emulation
• Keyboard layout
GERMAN
• Framing
’
ENTER
’
• No read character
none
• Streaming presentation mode
Figure 7.4:
Configuration code USB standard parameters (keyboard emulation)
As an alternative to USB keyboard emulation,
USB COM port emulation
is also possible
with the following parameters:
• Framing
<STX>
DATA
<CR><LF>
• No read character
’
?
’
• Manual trigger mode
start command:
<SYN>T<CR>
stop command:
<SYN>U<CR>
Please read in the following configuration code to set these parameters.
Figure 7.5:
Configuration code for USB COM port emulation
Notice!
The Windows driver for USB COM port emulation can be found in the download area at
www.leuze.com.