Display and control panel
Leuze electronic
Technical description LES
57
TNT
35/7-2
4
V
Net Mask Address
255.255.255.000
Here you can set the relevant subnet
mask.
Port Number Local
9008
Here you can set the local port (at the
LES) for Ethernet communication.
Port Number Dest.
5634
Here you can set the destination port
for Ethernet communication (on the
PC/process control).
Notice
: The values configured here
are not applied immediately but only
when the sensor is switched on the
next time.
Ethernet
Factory Settings
Factory Settings
Inactive
Factory Settings
Inactive
If you press
here, you can access
the superordinate menu without
resetting to factory settings.
X
Factory Settings
Execute
If you press
here, you will reset the
LES to factory settings (chapter 7.3).
Factory Settings
Inactive
Password Check
Inactive
Locks access to the menu with
the fixed password "165"
Password Check
Inactive
If you press
here, the password
query will not be activated.
X
Password Check
Activated
If you press
here, the password
query will be activated.
Password Check
Inactive
Slave Address
126
Slave Address
126
Here, you can set the PROFIBUS
address of the LES (0 … 126). With
address 126 (default), automatic
address assignment by the commis-
sioning master is supported.
Slave Address
126
Level 1
Level 2
Level 3
Explanation / Notes
Default
Table 7.2:
Menu structure