16
LINK LED
Tab. 3.3:
LINK indicators
Color
State
Description
Green
ON (continuous light)
Ethernet connected (LINK)
Yellow
Flashing
Data communication (ACT)
Feedback LEDs
Tab. 3.4:
Feedback LED indicators
Color
State
Description
---
OFF
Device off
No operating voltage
No positioning operation active
No marker found or marker not in the corresponding quadrant
Green
Flashing
Flashing frequency signals the marker distance to the nominal
position:
• Low frequency: Large distance
• High frequency: Short distance
ON (continuous light)
Marker is in nominal position (coordinate origin).
The positioning sensor is optimally positioned if all four feed-
back LEDs illuminate.
3.4.2
Function selection and program selection
Function selection
The following functions are selected and displayed via the bar graph display (see chapter 8.6 "Activating
device functions"):
•
AUTO
: Auto setup function for determining the optimum exposure and marker settings. Additional
teaching of the position in the selected program, if possible.
•
ADJ
: Adjustment function for aligning the device and for teaching-in the position in the current program
The individual functions are selected and activated with the control buttons.
• Select function with the navigation button
: The function LED flashes.
• Activate function with the enter button
: The function LED illuminates continuously.
NOTICE
If you activate the
AUTO
or
ADJ
function via the control buttons, the device accepts no com-
mands via the process interface. Process mode is thereby interrupted.
Program selection
The control buttons and PROGRAM display can be used to select, activate and display programs that are
stored in the device.