Mounting distance for parallel operation with AMS 300/AMS 200 laser measurement systems
The mounting of an AMS 300/AMS 200 laser measurement system does not affect data transmission if
the minimum mounting distances of the devices to the AMS are maintained and the devices are correctly
aligned.
• Details on the permissible reflector types can be found in the “Technical description” of the AMS 300/
AMS 200.
Reflector sizes from 200 x 200 mm to 1000 x 1000 mm are permissible.
• Only one reflector may be mounted next to the device.
The minimum mounting distance to be maintained to the reflector is dependent on the operating range of
the devices.
Table 4.3:
Minimum mounting distance to the reflector of the AMS 300/AMS 200
1
Minimum mounting distance
Figure 4.14: Minimum mounting distance to the reflector
Range of the device
Minimum mounting distance
40 m (DDLS_5XX 40...)
0 mm
120 m (DDLS_5XX 120...)
250 mm