Device description
Leuze electronic
DDLS 508
14
1
PWR – Supply voltage (Power)
2
TMP – Temperature warning/error
3
LSR – Laser prefailure message
4
FRE - Indicates the preselected transmission frequency
5
OLK – Optical link
6
ERL – Error Link
7
LINK – M12 cable-connected link
Figure 3.5: Operating state LEDs in the control panel
Table 3.2:
Meaning of the operating state indicators
1
2
3
4
5
6
7
LED
Color
State
Description
PWR
---
OFF
No supply voltage (see chapter 7.1)
Green
Flashing
Device is being initialized
• Supply voltage connected
• Initialization running
• No data sent or received
Green
Continuous
light
Data transmission path ready
• Initialization finished
Red
Flashing
Warning set (see chapter 7.1)
• No green and orange LEDs in SIGNAL QUALITY indicator
• The optical link is interrupted.
• The laser diode of the transmitter is defective.
Red
Continuous
light
Device error (see chapter 7.1)
• The function of the device is limited.
The displays of the other operating state LEDs may provide
information on the cause of the error.
TMP
---
OFF
Operating temperature in the specified working range
Orange
Continuous
light
• Warning: The operating temperature is above or below the
specified working range by a maximum of 5 °C (see
• Data transmission remains active.
Red
Continuous
light
• The operating temperature is above or below the specified
working range by more than 5 °C (see chapter 7.1).
• The operating time outside of the permissible operating tem
-
perature is detected by the device.
• Data transmission remains active.