Technical data
Leuze electronic
CSL 710
82
15
Technical data
15.1 General specifications
Table 15.1:
Optical data
Table 15.2:
Measurement field data: Operating range limit and measurement field length of the
CSL 710i
Table 15.3:
Operating ranges CSL 710
Table 15.4:
CSL 710 profile and measurement field lengths
Light source
LED (modulated light)
Wavelength
940 nm (infrared light)
Beam spacing [mm]
Typ. op. range limit
a)
[m]
Measurement field length
b)
[mm]
min.
max.
min.
max.
5
0.1
4.5
160
2960
10
0.2
9.0
160
2880
20
0.2
9.0
150
2870
40
0.2
9.0
290
2850
a) Typ. operating range limit: min./max. attainable range without function reserve for parallel-beam scanning.
b) Measurement field lengths and beam spacings specified in fixed rasters, see ordering table.
Beam spacing [mm]
Operating range [m]
Parallel-beam
Operating range [m]
Diagonal-beam
Operating range [m]
Crossed-beam
min.
max.
min.
max.
min.
max.
5
0.1
3.5
0.2
2.6
0.2
2.2
10
0.3
7.0
0.3
5.2
0.3
4.4
20
0.3
7.0
0.3
5.2
0.3
4.4
40
0.3
7.0
0.6
5.2
0.6
4.4
Measurement field
length B [mm]
Measurement field
length B [mm]
Measurement field
length B [mm]
Measurement field
length B [mm]
Profile length L
[mm]
with beam spacing A
5 mm
with beam spacing A
10 mm
with beam spacing A
20 mm
with beam spacing A
40 mm
160
160
150
-
168
240
-
-
-
248
320
320
310
290
328
400
-
-
-
408
480
480
470
-
488
560
-
-
-
568