Example configurations
Leuze electronic
CSL 710
67
Map pin 5 to configured height area 2.
10.3 Example configuration - Activating and deactivating blanking areas
10.3.1 Configuration of blanking areas (general)
Perform the following settings to activate or deactivate blanking areas.
Example: automatic blanking of two areas during teaching
Example: Deactivation/resetting of auto blanking
10.4 Example configuration – smoothing
10.4.1 Smoothing configuration (general)
Make the following settings for smoothing.
Example: Smoothing of four interrupted beams
Description / variables
Configuration of digital inputs/outputs
IO Function
Value: 3 = Area output (area 1 … 8)
The area output signals the logical states of beam
areas 1 … 8
Description / variables
Configuration of pin 5
Area mapping 8 … 1
(OR combination)
0b00000010
Blanking settings
Parameter
Number of auto blanking areas
:
= 2
Two blanking areas permitted
Parameter
Auto blanking (during teaching)
:
= 1
Automatic blanking-area configuration active
System commands
Parameter
Teach command
:
= 1
Execute teach command
Blanking settings
Parameter
Number of auto blanking areas
:
= 0
No blanking areas permitted
Parameter
Auto blanking (during teaching)
:
= 0
Automatic blanking area configuration not active
Blanking settings
Parameter
Function for blanking area/logical value
for blanking area 1
:
= 0
No beams blanked
Parameter Function for blanking area/logical value
for blanking area 2:
= 0
No beams blanked
System commands
Parameter
Teach command
:
= 1
Execute teach command
Smoothing settings
Parameter
Smoothing -– less than i interrupted
beams are ignored
:
= 4
Beams are taken into account in the evaluation once
there are four or more interrupted beams