Leuze electronic webConfig tool – Extended configuration
Leuze electronic
BPS 307i
67
Configuration of position monitoring (
DATA PROCESSING
tab,
Position
>
Monitoring
)
• Position limit value 1/2
Signals that the position value is outside of the configured limit value range.
Configuration of speed detection (
DATA PROCESSING
tab,
Speed
>
Detection
)
• Speed measurement averaging
Measurement value preparation averages all speed values calculated during the selected period
(averaging) to yield a speed output value.
• Scaling free resolution
Free scaling of the output of the speed values.
• Error handling procedures
Parameters for the speed value in case of failure.
Configuration of speed monitoring (
DATA PROCESSING
tab,
Measurement data
>
Speed
>
Monitoring
)
• Speed limit value 1-4
Signals that the speed is outside of the configured limit value range.
Configuration of the measurement value display (
DATA PROCESSING
tab,
General preparation
)
Unit of measurement: metric or inch
• Counting direction
Count direction for position calculation or sign for speed calculation.
• Output mode sign
Output mode of the sign. Affects position value and speed output.
Configuration of monitoring of the reading quality (
DATA PROCESSING
tab,
Reading quality
)
• Warning threshold for reading quality in %
• Error threshold for reading quality in %
Configuration of the communication data (
COMMUNICATION
tab)
• Configuration of the SERVICE USB interface
• Selection of the master clock frequency according to the request frequency of the control (master):
• 80 kHz - 800 kHz
• 50 kHz - 79 kHz
• Update rate of the measurement values on the SSI interface. The measurement value is updated
independent of the clock frequency.
• 2 ms
• 1 ms
• 200 µs
• 50 µs
9.3.3
ALIGNMENT
function
The
ALIGNMENT
function serves to simplify mounting and alignment of the BPS. The laser is to be acti
-
vated via the Start icon so that the function can monitor and directly display the measurement values for
position and speed and determine the optimum installation location.
In addition, reading quality (in %), working distance and the number of labels in the scanning beam can be
displayed. Using this information, it is possible to assess how well the BPS is aligned with the BCB.
NOTICE
ALIGNMENT
function only in the
Service
operating mode!
The BPS can only be aligned using the
ALIGNMENT
function in the
Service
operating mode.