38
BCL 558
i
Leuze electronic
5.2.2
Oscillating-mirror scanner with heating
Specifications are the same as for line scanner without heating with the following differ-
ences:
Type
BCL 558
i
EtherNet/IP
Type
Oscillating-mirror scanner with heating
Optical data
Useful opening angle
Max. 50°
Max. swivel angle
±12°(adjustable)
Electrical data
Operating voltage
24VDC ±20%
Power consumption
Max. 75W
Structure of the heating
Housing heating and separate heating of the optics glass
Warmup time
Min. 30min at +24VDC and an ambient temperature of -35°C
Min. conductor
cross-section
Conductor cross-section of at least 0.75mm² for the supply-voltage
supply line.
Wiring through of the voltage supply to multiple heating devices is
not
permissible.
Standard, M12 ready-made cable
not
usable
(insufficient cable cross-section)
Environmental data
Operating temperature range -35°C … +40°C
Storage temperature range
-20°C … +70°C
Table 5.5:
Specifications of the BCL 558
i
oscillating-mirror scanners with heating