Fast commissioning / operating principle
20
BCL 548
i
Leuze electronic
3.5.3
Configuration
Configure the PROFINET-IO system with the HW Config of the SIMATIC Manager by
inserting the BCL 548
i
into your project.
Figure 3.2:
Assignment of the device names to IP addresses
Here, an IP address is assigned to a unique "device name".
3.5.4
Transfer of the configuration to the IO Controller
Transfer the PROFINET-IO configuration to the IO Controller (S7 PLC).
After the correct transfer to the IO Controller (S7 PLC), the PLC automatically carries
out the following activities:
• Check device names
• Assignment of the IP addresses that were configured in the HW Config to the
IO devices
• Establishment of a connection between the IO Controller and configured IO devices
• Cyclical data exchange
Notice!
Participants that have not been "named" cannot be contacted yet at this point in time!