10.14 Data output
10.14.1 Module 80 – Sorting
PROFINET-IO module identifier
Module-ID 1080
Submodule-ID 1
Description
Module to support the sorting of the output data.
Parameter
Parameter length
3 byte
Input data
None
Output data
None
Parameter
Description
Addr.
Data type Value range
Default
Unit
Sort
criterion 1
Specifies the crite-
rion according to
which sorting takes
place.
0.0
…
0.6
BitArea
0: No sorting
1: Sorting according to scan number
2: Sorting according to position in the scanning
beam
3: Sorting according to the oscillating mirror
position
4: Sorting according to the decoding quality
5: Sorting according to the bar code length
6: Sorting according to the code type number
7: Sorting according to the decoding direction
8: Sorting according to the bar code content
9: Sorting according to time
10: Sorting according to scanning duration
11: Sorting according to the code list (in which
the enabled bar codes are listed)
12: Sorting according to the identifier list
0
-
Sort
direction 1
Specifies the sorting
direction.
0.7
Bit
0: In ascending order
1: In descending order
0
-
Sort
criterion 2
Specifies the crite-
rion according to
which sorting takes
place.
1.0
…
1.6
BitArea
See sorting criterion 1
0
-
Sort
direction 2
Specifies the sorting
direction.
1.7
Bit
See sorting direction 1
0
-
Sort
criterion 3
Specifies the crite-
rion according to
which sorting takes
place.
2.0
…
2.6
BitArea
See sorting criterion 1
0
-
Sort
direction 3
Specifies the sorting
direction.
2.7
Bit
See sorting direction 1
0
-
Table 10.51: