Commissioning and configuration
Leuze electronic
BCL 548
i
175
TNT
35/7-2
4
V
10.12.5 Module 64 – Oscillating mirror
PROFINET-IO module identifier
Module-ID 1064
Submodule-ID 1
Description
Module for supporting the oscillating mirror.
Parameter
Parameter length
6 byte
Input data
None
Output data
None
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Oscillation mode
This parameter defines the mode in
which the oscillating mirror oper-
ates.
0.0 … 0.1 UNSIGNED8
0: Single oscillation
1: Double oscillation
2: Continuous oscilla-
tion
3: Continuous oscilla-
tion, oscillating mir-
ror moves to the
start position at the
end of the reading
gate.
2
-
Decoding direc-
tion
Setting of oscillating direction in
which the bar codes to be read must
be decoded.
0.4 … 0.5 BitArea
0: In both directions
1: During
forward
oscillation
2: During
backward
oscillation
0
-
Start position
Start position (opening angle) rela-
tive to the zero position of the swivel
range.
1 … 2
SIGNED16
-200 … +200
200
1/10°
Stop position
Stop position (opening angle) rela-
tive to the zero position of the swivel
range.
3 … 4
SIGNED16
-200 … +200
-200
1/10°
Oscillation fre-
quency
Common value for forward and
backward motion
5
UNSIGNED8
15 … 116
48
°/s
Table 10.41:
Parameters for module 64