Commissioning and configuration
Leuze electronic
BCL 548
i
163
TNT
35/7-2
4
V
10.11 Identifier
The following modules can be used to specify the segmentation process to be used when
extracting identifiers from the bar code data.
When a module is configured, the associated segmentation process is activated. If none of
the modules is configured, no segmentation takes place.
Therefore, the modules can only be used one at a time and not simultaneously.
Notice!
When using one of the following modules, multiple results may occur within a reading gate.
If there are multiple results, acknowledge mode must be used (cf. "Module 10 – Activations"
on page 141, "Mode" parameter and the additional notices); data may otherwise be lost!
10.11.1 Module 52 – Segmentation according to the EAN process
PROFINET-IO module identifier
Module-ID 1052
Submodule-ID 1
Description
The module activates the segmentation according to the EAN process. The parameters
specify the identifiers to searched for and the output mode.
Parameter
Parameter
Description
Addr
.
Data type
Value range
Default
Unit
Identifier list
Identifier 1
The identifier string is used for the identifier list
and the filtering according to the segmenta-
tion.
0
STRING
5 characters null
terminated
1 … 5 bytes of
ASCII characters
‘*‘
-
Identifier 2
See identifier 1.
5
STRING
5 characters null
terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier 3
See identifier 1.
10
STRING
5 characters null
terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier 4
See identifier 1.
15
STRING
5 characters null
terminated
1 … 5 bytes of
ASCII characters
\0
-
Identifier 5
See identifier 1.
20
STRING
5 characters null
terminated
1 … 5 bytes of
ASCII characters
\0
-
Table 10.31:
Parameters for module 52