Commissioning and configuration
146
BCL 548
i
Leuze electronic
10.8.4
Module 13 – Fragmented read result
PROFINET-IO module identifier
Module-ID 1013
Submodule-ID 1
Description
The module defines the transfer of fragmented read results. To occupy few i/o-data, the read
results may be split into several fragments with this module. The fragments can then be
transmitted one after another with a handshake.
Parameter
Parameter length
1 byte
Input data
Input data length
2 byte consistent
Output data
None
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Fragment length
The parameter defines the maximum
length of the bar code information per
fragment.
0
UNSIGNED8
1 … 28
1
-
Table 10.12:
Parameters for module 13
Input data
Description
Addr.
Data type
Value range
Init value Unit
Fragment number
Current fragment number
0.0 … 0.3
Bitarea
0 … 15
0
-
Remaining frag-
ments
Number of fragments which still
have to be read for a complete
result.
0.4 … 0.7
Bitarea
0 … 15
0
-
Fragment size
Fragment length, always corre-
sponds to the configured fragment
length, except for the last frag-
ment.
1
UNSIGNED8
0 … 28
0
-
Table 10.13:
Input data for module 13