Commissioning and configuration
Leuze electronic
BCL 548
i
143
TNT
35/7-2
4
V
10.8.2
Module 11 – Reading gate control
PROFINET-IO module identifier
Module-ID 1011
Submodule-ID 1
Description
With the module, the reading gate control of the bar code reader can be adapted to the appli-
cation. With different parameters from the bar code reader, a time-controlled reading gate
may be created. In addition, it defines the internal criteria for the reading gate end and the
completeness inspection.
Parameter
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Automatic
reading gate
repeat
The parameter defines the
automatic repeat of read-
ing gates
0
Byte
0: No
1: Yes
0
-
Reading gate
end mode/
completeness
mode
This parameter can be
used to configure the com-
pleteness inspection.
1
Byte
0:
Independent of decoding
, i.e., the
reading gate is not terminated pre-
maturely.
1:
Dependent on decoding
, i.e, the
reading gate is terminated if the
configured number of bar codes to
be decoded has been reached.
1)
2:
DigitRef table-dependent
, i.e., the
reading gate is terminated if each
bar code stored in the code type
table has been decoded.
2)
3:
Ident list dependent
, i.e., the read-
ing gate is terminated if each iden-
tifier stored in a list could be
segmented via a respective bar
code segmentation.
3)
4:
Reference code comparison
, i.e.,
the reading gate is terminated if a
positive reference code comparison
has taken place.
4)
1
-
Table 10.9:
Parameters for module 11