Commissioning and configuration
136
BCL 504
i
Leuze electronic
10.8.14 Module 41 – Code position in the swivel range
Description
The module defines input data for the communication of the relative barcode position in the
swivel range of an oscillating mirror device.
Parameters
None
Input data
Input data length
2 byte
Output data
None
Input data
Description
Addr.
Data type
Value range
Init
value
Unit
Position in the
swivel range
Relative position of the barcode in the
swivel range. The position is normal-
ised to the zero position (middle posi-
tion). Specified in 1/10 degrees.
0 … 1
SIGNED16
-200 … +200
0
1/10°
Table 10.31:
Input data for module 41