Important Parameters
Leuze electronic
BCL 21/22
61
TNT 35/7-24V
10.6
Switching input
Figure 10.8: Standard setting of the switching input menu
Notice!
If the switch-off delay is activated, the parameter "pulse duration" should be "0".
Invert
Here, the input level can be inverted.
Enable
Switching input enabled or disabled.
Debounce time
This time period must lapse until the trigger signal is regarded as
valid.
Delay on time
The trigger signal is passed on delayed by the specified time period.
Pulse duration
If the value is higher than "0": duration of the activation, regardless of
how long the trigger signal has been present.
Delay off time
After the end of the trigger signal, the pulse is extended internally by
this time period.
Function
Event that is started when the switching input is activated.