![Leuze electronic AMS 384 Technical Description Download Page 46](http://html1.mh-extra.com/html/leuze-electronic/ams-384/ams-384_technical-description_1883976046.webp)
Display and control panel AMS 384i
43
AMS 384
i
Leuze electronic
I/O submenu
Table 8.4:
I/O submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
I/O 1
Port
configuration
Input/Output
Defines whether I/O 1 functions as an output or input.
Output
Switching
input
Function
No function/preset teach/laser ON/OFF
Input LOW = laser ON, HIGH = laser OFF
Laser ON/OFF
Activation
Low active/High active
Low active
Switching
output
Function
No function
Activation
Low active/High active
Low active
I/O 2
Port config-
uration
Input/Output
Defines whether I/O 2 functions as an output or input.
Output
Switching
input
Function
No function
Activation
Low active/High active
Low active
Switching
output
Function
Output = High, if the travel speed is faster than 0.2 m/s
Velocity
monitoring
Activation
Low active/High active
Low active
Limit values
Upper pos.
limit 1
Activation
ON / OFF
OFF
Limit value
input
Value input in mm or inch/100
0
Lower pos.
limit 1
Activation
ON / OFF
OFF
Limit value
input
Value input in mm or inch/100
0
Upper pos.
limit 2
Activation
ON / OFF
OFF
Limit value
input
Value input in mm or inch/100
0
Lower pos.
limit 2
Activation
ON / OFF
OFF
Limit value
input
Value input in mm or inch/100
0