DeviceNet interface
Leuze electronic GmbH + Co. KG
AMS 355
i
69
TNT
35/7-2
4V
9.6.3.12 Warnings
Attribute 47
According to the CIP specification, warning messages are messages that signal exceedance
of internal limit values, but do not lead to incorrect measurement values.
As warnings, the AMS 355
i
enters the ATT, LSR and TMP status messages. A range for
device-specific data is reserved for this purpose in the CIP specification (bits 13 to 15).
9.6.3.13 Supported warnings
Attribute 48
Attribute 48 indicates which warnings specified by the position sensor object are supported
by the AMS 355
i
.
Bit 13 = 1; TMP warning is supported by the AMS 355
i
.
Bit 14 = 1; LSR warning is supported by the AMS 355
i
.
Bit 15 = 1; ATT warning is supported by the AMS 355
i
.
Bit 0 to bit 12 = 0
9.6.3.14 Warning flag
Attribute 49
The attribute evaluates the warnings supported in attribute 48, in an OR function (collective
warning).
9.6.3.15 Operating time
Attribute 50
The value is incremented in 1/10 hours for as long as the AMS 355
i
is connected to voltage.
The value cannot be reset.
9.6.3.16 Preset value
Attribute 100
The attribute enables the current position value to be set to a desired position value.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
–
–
–
–
–
–
–
–
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
ATT
LSR
TMP
–
–
–
–
–
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
–
–
–
–
–
–
–
–
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
1
1
1
–
–
–
–
–