
Fast commissioning / operating principle
Leuze electronic
AMS 307
i
11
TNT
35/7-2
4
V
3
Fast commissioning / operating principle
Notice!
Below, you will find a
short description of the initial commissioning
of the AMS 307
i
. De-
tailed explanations of the listed points can be found throughout the handbook
.
3.1
Mounting the AMS 307
i
The AMS 307
i
and the corresponding reflector are mounted on two mutually opposing,
plane-parallel, flat walls.
Figure 3.1:
Schematic illustration of mounting
Attention!
For error-free position measurement, there must be an unobstructed line-of-sight between
the
AMS 307
i
and the reflector.
3.1.1
Mounting the device
The laser is mounted using 4 screws (M5).
Alignment is performed using 2 adjustment screws. Adjust so that the laser light spot is posi-
tioned at the center of the reflector. The alignment is to be secured with the knurled nut and
locked with the M5 nut.
Further information can be found in chapter 5.2 and chapter 5.3.
3.1.2
Mounting the reflector
The reflector is mounted using 4 screws (M5). The reflector is angled using the spacer
sleeves included. Incline the reflector by approx. 1°.
Detailed information can be found in chapter 6.4.