Device parameters and interfaces
90
AMS 200
Leuze electronic
8
.
3
.7
Default settings of the AMS 200/…-20…
Table 8.16:
Default settings of the Interbus interface
Notice
!
The AMS 200 cannot be configured via the Interbus.
The settings labelled with footnote 1) can only be changed via the display. Changed param-
eters are stored in the AMS 200 and are reactivated following power off/on.
Default parameters of the AMS 200/xxx-20-(H)
Interbus activation
1)
1)
Parameter can be changed via the control panel/display
ON
RS2
3
2 activation
1)
OFF
Ident-Code
3
2H
Number of data bits
3
2
Data breakdown
2
3
-bit measurement value, 1-bit sign, 2-bit reserved,
3
-bit pre-failure mes-
sages, 2-bit errors, 1-bit statically set to binary
1
Measurement value represen-
tation
1)
Gray
Unit
1)
Metric
Resolution
1)
1mm
Count direction
1)
Positive
I/O 1
1)
Input LOW = laser on, HIGH = laser off
I/O 2
1)
Velocity monitoring output set to > 0.2m/s (configurable)
Static preset
1)
+ 000.000
Dynamic preset
1)
+ 000.000
Pos. limit value range 1
1)
Lower and upper limit, both 000.000
Pos. limit value range 2
1)
Lower and upper limit, both 000.000
Error handling procedures
1)
Position output: 000.000
Position status suppression: active
Error delay time: 100ms
Display language
1)
English
Display illumination
1)
Off after 10 min.
Display contrast
1)
medium
Password protection
1)
Off
Password
1)
0000