Device parameters and interfaces
Leuze electronic
AMS 200
7
3
TNT
3
5/7-2
4
V
8
.1.6.16 Module 16: Velocity status
Description
This module supplies the PROFIBUS master with various status information for velocity
measurement.
Parameter
none
Input data
Input data
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr. inch
Velocity
measure-
ment error
Signals that no valid velocity
could be ascertained.
1.0
Bit
0: OK
1: Error
–
–
–
Movement
status
Signals whether a movement
>0.1 m/s is currently being
detected.
1.1
Bit
0: No movement
1: Movement
–
–
–
Movement
direction
When the movement status is
activated, this bit indicates the
direction.
1.2
Bit
0: Positive direction
1: Negative direction
–
–
–
Velocity
limit value
status 1
Signals that limit value 1 has
been exceeded.
1.
3
Bit
0: Limit value
maintained
1: Limit value violated
–
–
11c
Velocity
limit value
status 2
Signals that limit value 2 has
been exceeded.
1.4
Bit
0: Limit value
maintained
1: Limit value violated
–
–
12c
Velocity
limit value
status
3
Signals that limit value
3
has
been exceeded.
1.5
Bit
0: Limit value
maintained
1: Limit value violated
–
–
1
3
c
Velocity
limit value
status 4
Signals that limit value 4 has
been exceeded.
1.6
Bit
0: Limit value
maintained
1: Limit value violated
–
–
14c
Dynamic
velocity
limit value
status
Signals that the dynamic limit
value has been exceeded.
1.7
Bit
0: Limit value
maintained
1: Limit value violated
–
–
15bd
Velocity
comparison
limit value 1
Signals whether the current
velocity is compared with this
limit value.
0.
3
Bit
0: Comparison not
active
1: Comparison active
–
–
–
Velocity
comparison
limit value 2
Signals whether the current
velocity is compared with this
limit value.
0.4
Bit
0: Comparison not
active
1: Comparison active
–
–
–
Velocity
comparison
limit value
3
Signals whether the current
velocity is compared with this
limit value.
0.5
Bit
0: Comparison not
active
1: Comparison active
–
–
–
a
b
c
d
e
f
g
h
i
j
k
Summary of Contents for AMS 200