Device parameters and interfaces
66
AMS 200
Leuze electronic
8
.1.6.12 Module 12: Static velocity limit value 2
Description
The
static velocity limit value 2
function compares the current velocity with a velocity
stored in the configuration. This occurs in the configured range, which is defined by
range
start
and
range end
.
Notice
!
If
range start
and
range end
are identical, velocity monitoring is not activated.
If a direction-dependent limit value check is activated via the
direction selection
parameter,
the values of
range start
and
range end
also define the direction. The check is always
performed from
range start
to
range end
. For example, if the range start is "5500" and the
range end is "5000", the direction-dependent check is only performed in the direction from
"5500" to "5000". The limit value is not active in the opposite direction.
If the check is independent of direction, the order of
range start
and
range end
is irrelevant.
Depending on the selected
switching mode
, if the value is above or below the defined
limits, the limit value status in module 16 is set and, if configured, the output is appropriately
set via module 4 or 5.
Parameter
Parameter
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
inch
Switching
mode
Condition for the "velocity limit
value 2" signal, which applies to
the output (module 4/5) and the
status bit (module 16).
0.0
Bit
0: Value greater than
limit
1: Value less than limit
0
–
–
Direction
selection
Selection of direction-depend-
ent or direction-independent
limit value checking.
0.1
Bit
0: Direction inde-
pendent
1: Direction dependent
0
–
–
Velocity
limit value
2
Limit value is compared to the
current velocity.
1…2
unsign
16 bit
0 … 20000
0
mm/s
(in/
100)
/s
16e
Velocity
hysteresis
2
Relative shift to prevent signal
bouncing.
3
…4
unsign
16 bit
0 … 20000
100
mm/s
(in/
100)
/s
–
Limit value
2 range
start
The velocity limit value is moni-
tored beginning at this position.
5…8
sign
3
2 bit
-999999 … +999999
0
mm
in/
100
–
Limit value
2 range
end
The velocity limit value is moni-
tored up to this position.
9
…
12
sign
3
2 bit
-999999 … +999999
0
mm
in/
100
–
Parameter length: 1
3
bytes
a
b
c
d
e
f