Device parameters and interfaces
56
AMS 200
Leuze electronic
8
.1.6.6
Module 6: Status and control
Description
This module supplies various AMS 200… status information to the PROFIBUS master. The
laser can be controlled via the master's output data.
Parameter
none
Input data
Input data
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr. inch
Laser
status
Signals the laser status.
1.0
Bit
0: Laser ON
1: Laser OFF
–
–
–
Preset
status
Status of the preset value.
1.1
Bit
0: Preset not active
1: Preset active
–
–
–
Preset teach
This bit toggles on each teach
event of a preset value.
1.2
Bit
0 or 1
–
–
–
Overflow
The output value has exceeded
the maximum value which can
be represented by the SSI inter-
face. In the event of an overflow
the SSI interface data are set to
0xFF.
1.
3
Bit
0: OK
1: Overflow
–
–
–
Intensity
(ATT)
If the intensity of the received
signal is less than the warning
threshold, the status bit is set.
1.4
Bit
0: OK
1: Warning
–
–
–
Tempera-
ture (TMP)
If the internal device tempera-
ture exceeds or drops below the
set limit value, the status bit is
set.
1.5
Bit
0: OK
1: Temperature above/
below limit
–
–
–
Laser (LSR)
Laser prefailure message.
1.6
Bit
0: OK
1: Laser warning
–
–
–
Plausibility
(PLB)
If implausible measurement val-
ues are diagnosed, the status
bit is set.
1.7
Bit
0: OK
1: Implausible meas-
urement value
–
–
–
Hardware
(ERR)
If a hardware error is diagnosed,
the status bit is set.
0.0
Bit
0: OK
1: Hardware error
–
–
–
Lower posi-
tion limit
value 1
Signals that the value is less
than lower limit value 1.
0.4
Bit
0: OK
1: Value less than limit
–
–
–
Upper posi-
tion limit
value 1
Signals that the value is greater
than upper limit value 1.
0.5
Bit
0: OK
1: Value greater than
limit
–
–
–
a