9.1.3.2 System deactivation
Command
-
Command with default framing
<STX>-<ETX>
Answer with default framing
<STX>-=OK<ETX>
Description
9.1.3.3 Data Reset
Command
DR
Command with default framing
<STX>DR<ETX>
Answer with default framing
<STX>DR=OK<ETX>
Description
Resets the output data of the host interface.
This only affects data fields. Status and error codes are not reset.
The internal object counter of the system is not affected by this; it continues to run as usual during
the next measurement.
Example:
Output before command “DR”: <STX>00004,00300,00400,00050,+02,035,000<ETX>
Cyclic output after command
“DR”: <STX>00000,00000,00000,00000,000,035,000<ETX>
Output after next measurement: <STX>00005,00300,00395,00050,000,035,000<ETX>
9.1.3.4 Clear error
Command
EC
Command with default framing
<STX>EC<ETX>
Answer with default framing
<STX>EC=OK<ETX>
Description
Confirms and deletes any errors or warnings in the system.
9.1.3.5 Soft restart of the system
Command
SRS
Command with default framing
<STX>SRS<ETX>
Answer with default framing
<STX>SRS=OK<ETX>
Description
Executes an internal reset of the system modules.
This process takes a few seconds.
There must be no object in the measuring frame during the reset.
The process also resets the system's internal object counter, which starts from zero again after the
reset has been completed.
9.1.3.6 Hard restart of the system
Command
SRH
Command with default framing
<STX>SRH<ETX>
Answer with default framing
No answer
(Executes an immediate reset)
Description