Leuze electronic
CMS 700i
– Contour Measurement System
Page 25
5.2.6 Positioning width measurement
NOTICE
Must be observed!
For the highest performance reserve even with very small gaps between the rollers of the
conveyor, the transmitter must be mounted exactly in the middle between two rollers and parallel
to it!
The full width of the conveyor must be covered by the measuring length of the width light
curtain!
Set up the smallest gap between the rollers of the conveyor at ≥10 mm so that the width light
curtain can shine through.
5.2.7 Positioning length measurement
NOTICE
Must be observed!
Transmitter and receiver must be aligned in one focus line!
The plane spanned by the light beams of the light curtain must be parallel to the conveying
direction!
The plane spanned by the light beams of the light curtain must be aligned parallel to the plane
of the conveyor!
Tilting between transmitter and receiver must be avoided!
Figure 17: View of the min. object height on the length light curtain. The conveying direction points to the sheet level.
Object width
Smallest object height
Conveyor
Level length light curtain
Distance level/conveyor
Length light curtain
Conveying direction points to the sheet level