Leuze electronic
CMS 700i
– Contour Measurement System
Page 20
5 Mounting and installation
5.1 General information
The exact alignment of the light curtain pairs to each other directly influences the quality of the
measurement results. The system should be mounted on a largely vibration-free frame. Strong
vibrations can falsify the measurement result. The figures are valid across all interfaces for all
connection types. The respective interface chapters provide specific connection diagrams.
5.2 System with 3 light curtains
NOTICE
The following installation instructions must be observed!
The light curtains for height and width must be on the same level.
The first beam of the length light curtain must be in front of the plane of height and width.
The light curtains for length, width and height must be at right angles to each other.
The length light curtain must be oriented parallel to the conveying direction.
Figure 14: Schematic system structure with 3 light curtains; grey box is measuring object, grey circles are conveyor
rolls