![Leuze electronic 50038948 Original Operating Instructions Download Page 27](http://html.mh-extra.com/html/leuze-electronic/50038948/50038948_original-operating-instructions_1883900027.webp)
Accessories/order codes
Leuze electronic
BCL 8
25
TN
T 3
5/7-
24V
5.2.4
MA 8.1 - BCL - connecting the BCL 8 to the MA 8.1
Figure 5.1: MA 8.1 - Pin assignment BCL
The BCL 8 is connected to the MA 8.1 via the connection cable KB 008-1000/2000/3000
(AA/AR). The voltage supply is connected via the PWR IN HOST/RS232 socket.
BCL (5-pin socket, A-coded)
Pin
Name
Comment
1
VIN
Supply voltage for BCL 8
+4.9 … +5.4VDC
2
TXD RS 232 transmission line
3
GND Supply voltage: 0VDC
4
RXD RS 232 receiving line
5
SWIN/
SWOUT
Programmable switching input/output of the
BCL 8
Thread
FE
Functional earth (housing)
1
2
3
4
5
RXD
VIN
GND
SWIN/SWOUT
TXD
BCL 8
M12 socket
ATTENTION!
Degree of protection IP 67 is achieved only if the connectors and caps are screwed into
place!
ATTENTION!
It is absolutely necessary to connect the functional earth, since all electrical interference
(EMC coupling) is discharged via the functional earth connection.
UM_BCL8_de_50040581.book Seite 25 Montag, 24. Februar 2020 9:53 09