background image

 
 
 

LEONTON

 

PT2-0702-SFP-24 Series 

(PT2-0702-SFP-24 / PT2-0702-SFP-24-T)

 

 

 

 

 

 

User Manual

 

Summary of Contents for PT2-0702-SFP-24 Series

Page 1: ...LEONTON PT2 0702 SFP 24 Series PT2 0702 SFP 24 PT2 0702 SFP 24 T User Manual...

Page 2: ...t not limited to the implied warranties of merchantability and fitness for a particular purpose Leonton Technologies Co Ltd may make improvements and or changes to the product and or specifications of...

Page 3: ...equipment D claration FCC Cet quipement a t test et reconnu conforme aux limites de la classe A pour les quipements num riques conform ment la section 15 des R glementations FCC Ces limites sont con u...

Page 4: ...equired to take adequate measures CE Mark AVERTISSEMENT Ceci est un produit de classe A Dans un environnement domestique ce produit peut tre utilis en pr sence d interf rences radio This document is t...

Page 5: ...ption 3 Physical Dimensions 3 Front Panel 4 Top View 4 LED Indicators 5 Ethernet Ports 6 Cabling 7 Wiring the Power Inputs 9 Wiring the Fault Alarm Contact 11 Mounting Installation 12 DIN Rail Mountin...

Page 6: ...g temperature of 10 C 65 C and another with a wide operating temperature of 40 C 75 C this series is designed to meet any needs for industrial automation application and harsh environments Key Feature...

Page 7: ...switch s hardware specs ports cabling information and wiring installation will be described within this user manual ATTETNION Si la tension CC est fournie par un circuit externe veuillez utiliser un...

Page 8: ...Hardware Description Physical Dimensions Figure 2 1 below shows the physical dimensions of PT2 0702 SFP 24 series W x H x D is 46mm x 142mm x 99mm Figure 2 1 PT2 0702 SFP 24 Series Physical Dimension...

Page 9: ...n below in Figure 2 2 Figure 2 2 The Front Panel of PT2 0702 SFP 24 Series Top View Figure 2 3 below shows the top panel of the PT2 0702 SFP 24 series switch that is equipped with one 6 pin removal te...

Page 10: ...inactive Fault Red On Power input 1 or 2 is inactive Off Power input 1 and 2 are both functional SFP Port LINK ACT Green On Connected to the network Flashing Networking is active Off Not connected to...

Page 11: ...raight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 2 1000BASE T RJ 45...

Page 12: ...t optical transceiver used in optical communications for both telecommunication and data communication applications To connect the transceiver and LC cable please follow below steps Step 1 Insert the...

Page 13: ...ure 2 11 Figure 2 11 LC Connector to the Transceiver To remove the LC connector from the transceiver please follow the steps shown below Step 1 Press the upper side of the LC connector from the transc...

Page 14: ...the Power Inputs Please follow the below steps to insert the power wire Step 1 Insert the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as sh...

Page 15: ...10 Figure 2 15 Power Terminal Block Note Only use copper conductors 60 75 C tighten to 5 lbs The wire gauge for the terminal block should range between 18 20 AWG...

Page 16: ...luding power failure or port link failure managed industrial switch only and form a normally open circuit An application example for the fault alarm contact is shown below in Figure 2 16 Figure 2 16 W...

Page 17: ...ure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch Step 1 Use the screws to install the DIN Rail bracket on the rear si...

Page 18: ...ull down the bracket on to the rail as shown below in Figure 3 3 Figure 3 3 Stable the Switch on DIN Rail Step 5 Check if the bracket is mounted tightly on the rail Step 6 To remove the industrial Eth...

Page 19: ...strial Ethernet switch Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Step 4 Use the hook holes at the corners of the wall mounting bracket to hang the indu...

Page 20: ...to the Mounting Installation section Step 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you need help on how to wire power please refer to the Wiring the Powe...

Page 21: ...assist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist Please refer to the LED Indicators section for LED light indicat...